The foundation of electrical safety compliance
Important: Failing to test and tag can void your insurance and expose you to WHS liability.
Test and tag is the process of visually inspecting and electrically testing portable appliances to ensure they are safe for use in the workplace. Every item that passes receives a compliant tag showing the test date and next due date. Failed items are removed from service immediately.
Check for damaged cables, plugs, casings, and signs of overheating or misuse.
Verify the earth conductor provides a safe path for fault current.
Confirm insulation integrity between live conductors and earth.
Ensure active and neutral conductors are correctly connected.
Apply a compliant tag and log results in a digital asset register.
AS/NZS 3760:2022 + AS/NZS 3017
Your last line of defence against electrocution
Important: An untested RCD may fail to trip — leaving workers exposed to fatal electric shock.
Residual Current Devices (RCDs), also known as safety switches, are designed to cut power within milliseconds when a dangerous earth leakage current is detected — preventing electrocution. Regular testing is mandatory in most Australian states and is critical to ensuring they actually work when needed.
Verify the RCD trips correctly when the test button is pressed.
Measure the disconnection time under rated fault current — must be ≤300ms.
Confirm the RCD operates at or below its rated residual current.
Assess the total earth leakage current on the protected circuit.
Record trip times, test results, and schedule next test date.
AS/NZS 3760:2022 + AS/NZS 3000
Specialist testing for high-power industrial equipment
Important: 3-phase faults can cause fires, equipment damage, and serious injury — don't skip specialist testing.
Three-phase electrical systems power the heavy-duty equipment found in commercial kitchens, manufacturing plants, gyms, and industrial facilities. Testing 3-phase equipment requires specialist knowledge and equipment beyond standard single-phase testing — our technicians are fully qualified to handle it safely.
Verify voltage balance across all three phases to prevent motor damage.
Test insulation between each phase conductor and earth.
Confirm low-resistance earth path on all accessible earthing points.
Where safe, test under operational load to identify faults not visible at rest.
Detailed report with per-phase results, pass/fail status, and recommendations.
The Standard
AS/NZS 3760:2022 is the Australian and New Zealand standard for in-service safety inspection and testing of electrical equipment. It sets out the requirements for testing intervals, test methods, and documentation — and is referenced by WHS regulations across all Australian states and territories.
Under the Work Health and Safety Act, employers have a duty to ensure electrical equipment is safe. AS/NZS 3760 is the accepted method for demonstrating compliance.